On Mon, 18 Nov 2019 00:25:04 +0000 Dan Robertson <dan@xxxxxxxxxxxxxxx> wrote: > Sorry for the incredibly late reply. Before I submit the next patchset version, > I have a question from the last set of reviews. > > On Mon, Oct 21, 2019 at 04:20:16PM +0100, Jonathan Cameron wrote: > > On Sat, 19 Oct 2019 02:43:51 +0000 > > Dan Robertson <dan@xxxxxxxxxxxxxxx> wrote: > > > On Fri, Oct 18, 2019 at 10:23:38AM +0300, Andy Shevchenko wrote: > > > > On Fri, Oct 18, 2019 at 6:44 AM Dan Robertson <dan@xxxxxxxxxxxxxxx> wrote: > > > > > +static const int bma400_osr_table[] = { 0, 1, 3 }; > > > > > > > > > +/* See the ACC_CONFIG1 section of the datasheet */ > > > > > +static const int bma400_sample_freqs[] = { > > > > > + 12, 500000, > > > > > + 25, 0, > > > > > + 50, 0, > > > > > + 100, 0, > > > > > + 200, 0, > > > > > + 400, 0, > > > > > + 800, 0, > > > > > +}; > > > > > > > > This can be replaced by a formula(s). > > > > > > Yeah I think I can implement the get, set, and read functions for sample_freq > > > with a formula, but the scale and sample frequency tables are needed by the > > > implementation of read_avail. A implementation of read_avail with a range and > > > a step would be ideal, but I couldn't find any documentation on implementing > > > read_avail where the step value of the range is a multiple. Please correct > > > me if I've missed something. > > > > Indeed. We've only defined it as being fixed intervals. > > I'm not keen to expand the options for the userspace interface any > > further. > > > > You could compute the values at startup and store it in your state structure > > I think (or compute them on demand, but you'd need to have the space somewhere > > non volatile). > > > > I ended up writing an implementation that uses a formula for the get/set > functions of the sample frequency and scale, but uses a table for the > implementation of the read_avail function. While it does work, I worry > that this makes the driver less maintainable and would make it harder to > add support for a new hypothetical future BMA4xx device. Also, the majority > of drivers seem to use a table for the raw value to user input conversion, > so a move from this might make the code less "familiar". > > If we do stick with the translation table, would it be better to have two > tables (a translation table and a read_avail table) so that we do not have > a step distance of two? This would mean we would need to maintain two > tables, but would simplify the code. If a function is your preferred route you could also just use it to compute the values for the available table at startup? Otherwise, its fine to just use a table for both. > > Random workflow question: > > The sampling ratio, frequency, etc code seems to be the most complicated part > of the driver. Is it typically recommended to upstream a more minimal driver > that might assume the defaults? Often people upstream a first version that just uses defaults, then follow up (if they care) with later series adding the more fiddly elements. Sometimes those more fiddly bits never come as a particular author never needed them. That's absolutely fine. It's a rare driver that supports all the features on a non trivial device! Thanks, Jonathan > > Cheers, > > - Dan >