On 19-09-25 16:18, Adam Thomson wrote: > On 25 September 2019 16:52, Marco Felsch wrote: > > > Hi Adam, > > > > On 19-09-24 09:23, Adam Thomson wrote: > > > On 17 September 2019 13:43, Marco Felsch wrote: > > > > > > > Add the documentation which describe the voltage selection gpio support. > > > > This property can be applied to each subnode within the 'regulators' > > > > node so each regulator can be configured differently. > > > > > > > > Signed-off-by: Marco Felsch <m.felsch@xxxxxxxxxxxxxx> > > > > --- > > > > Documentation/devicetree/bindings/mfd/da9062.txt | 9 +++++++++ > > > > 1 file changed, 9 insertions(+) > > > > > > > > diff --git a/Documentation/devicetree/bindings/mfd/da9062.txt > > > > b/Documentation/devicetree/bindings/mfd/da9062.txt > > > > index edca653a5777..9d9820d8177d 100644 > > > > --- a/Documentation/devicetree/bindings/mfd/da9062.txt > > > > +++ b/Documentation/devicetree/bindings/mfd/da9062.txt > > > > @@ -66,6 +66,15 @@ Sub-nodes: > > > > details of individual regulator device can be found in: > > > > Documentation/devicetree/bindings/regulator/regulator.txt > > > > > > > > + Optional regulator device-specific properties: > > > > + - dlg,vsel-sense-gpios : The GPIO reference which should be used by the > > > > + regulator to switch the voltage between active/suspend voltage settings. > > If > > > > + the signal is active the active-settings are applied else the suspend > > > > + settings are applied. Attention: Sharing the same gpio for other purposes > > > > + or across multiple regulators is possible but the gpio settings must be the > > > > + same. Also the gpio phandle must refer to to the dlg,da9062-gpio device > > > > + other gpios are not allowed and make no sense. > > > > + > > > > > > Should we not use the binding names that are defined in 'gpio-regulator.yaml' > > as > > > these seem to be generic and would probably serve the purpose here? > > > > Hm.. as the description says: > > > > 8<-------------------------------------------------- > > gpios: > > description: Array of one or more GPIO pins used to select the > > regulator voltage/current listed in "states". > > 8<-------------------------------------------------- > > > > But we don't have a "states" property and we can't select between > > voltage or current. > > Yes I think I was at cross purposes when I made this remark. The bindings there > describe the GPOs that are used to enable/disable and set voltage/current for > regulators and the supported voltage/current levels that can be configured in > this manner. What you're describing is the GPI for DA9061/2. If you look at > GPIO handling in existing regulator drivers I believe they all deal with external > GPOs that are configured to enable/disable and set voltage/current limits rather > than the GPI on the PMIC itself. That's why I'm thinking that the configurations > you're doing here should actually be in a pinctrl or GPIO driver. That's true, the common gpio bindings are from the view of the processor, e.g. which gpio must the processor drive to enable/switch the regualtor. So one reasone more to use a non-common binding. Please take a look on my other comment I made :) I don't use the gpio-alternative function. I use it as an input. Regards, Marco > I'd be interested in hearing Mark's view on this though as he has far more > experience in this area than I do. > > > > > Regards, > > Marco > > > > > > - rtc : This node defines settings required for the Real-Time Clock associated > > > > with the DA9062. There are currently no entries in this binding, however > > > > compatible = "dlg,da9062-rtc" should be added if a node is created. > > > > -- > > > > 2.20.1 > > > > > > > > > > -- > > Pengutronix e.K. | | > > Industrial Linux Solutions | http://www.pengutronix.de/ | > > Peiner Str. 6-8, 31137 Hildesheim, Germany | Phone: +49-5121-206917-0 | > > Amtsgericht Hildesheim, HRA 2686 | Fax: +49-5121-206917-5555 | > -- Pengutronix e.K. | | Industrial Linux Solutions | http://www.pengutronix.de/ | Peiner Str. 6-8, 31137 Hildesheim, Germany | Phone: +49-5121-206917-0 | Amtsgericht Hildesheim, HRA 2686 | Fax: +49-5121-206917-5555 |