Hi Adam, On 19-09-24 09:23, Adam Thomson wrote: > On 17 September 2019 13:43, Marco Felsch wrote: > > > Add the documentation which describe the voltage selection gpio support. > > This property can be applied to each subnode within the 'regulators' > > node so each regulator can be configured differently. > > > > Signed-off-by: Marco Felsch <m.felsch@xxxxxxxxxxxxxx> > > --- > > Documentation/devicetree/bindings/mfd/da9062.txt | 9 +++++++++ > > 1 file changed, 9 insertions(+) > > > > diff --git a/Documentation/devicetree/bindings/mfd/da9062.txt > > b/Documentation/devicetree/bindings/mfd/da9062.txt > > index edca653a5777..9d9820d8177d 100644 > > --- a/Documentation/devicetree/bindings/mfd/da9062.txt > > +++ b/Documentation/devicetree/bindings/mfd/da9062.txt > > @@ -66,6 +66,15 @@ Sub-nodes: > > details of individual regulator device can be found in: > > Documentation/devicetree/bindings/regulator/regulator.txt > > > > + Optional regulator device-specific properties: > > + - dlg,vsel-sense-gpios : The GPIO reference which should be used by the > > + regulator to switch the voltage between active/suspend voltage settings. If > > + the signal is active the active-settings are applied else the suspend > > + settings are applied. Attention: Sharing the same gpio for other purposes > > + or across multiple regulators is possible but the gpio settings must be the > > + same. Also the gpio phandle must refer to to the dlg,da9062-gpio device > > + other gpios are not allowed and make no sense. > > + > > Should we not use the binding names that are defined in 'gpio-regulator.yaml' as > these seem to be generic and would probably serve the purpose here? Hm.. as the description says: 8<-------------------------------------------------- gpios: description: Array of one or more GPIO pins used to select the regulator voltage/current listed in "states". 8<-------------------------------------------------- But we don't have a "states" property and we can't select between voltage or current. Regards, Marco > > - rtc : This node defines settings required for the Real-Time Clock associated > > with the DA9062. There are currently no entries in this binding, however > > compatible = "dlg,da9062-rtc" should be added if a node is created. > > -- > > 2.20.1 > > -- Pengutronix e.K. | | Industrial Linux Solutions | http://www.pengutronix.de/ | Peiner Str. 6-8, 31137 Hildesheim, Germany | Phone: +49-5121-206917-0 | Amtsgericht Hildesheim, HRA 2686 | Fax: +49-5121-206917-5555 |