On 30/05/2019 9.56, Tony Lindgren wrote: > There is no CLKSEL for timer12 on dra6 unlike for timer1. This > causes issues on booting the device that Tomi noticed if > DEBUG_SLAB is enabled and the clkctrl clock does not properly > handle non-existing clock. Let's drop the bogus CLKSEL clock, > the clkctrl clock handling gets fixed separately. Tested-by: Peter Ujfalusi <peter.ujfalusi@xxxxxx> > Cc: Peter Ujfalusi <peter.ujfalusi@xxxxxx> > Cc: Tero Kristo <t-kristo@xxxxxx> > Cc: Tomi Valkeinen <tomi.valkeinen@xxxxxx> > Reported-by: Tomi Valkeinen <tomi.valkeinen@xxxxxx> > Fixes: 4ed0dfe3cf39 ("ARM: dts: dra7: Move l4 child devices to probe them with ti-sysc") > Signed-off-by: Tony Lindgren <tony@xxxxxxxxxxx> > --- > arch/arm/boot/dts/dra7-l4.dtsi | 2 -- > 1 file changed, 2 deletions(-) > > diff --git a/arch/arm/boot/dts/dra7-l4.dtsi b/arch/arm/boot/dts/dra7-l4.dtsi > --- a/arch/arm/boot/dts/dra7-l4.dtsi > +++ b/arch/arm/boot/dts/dra7-l4.dtsi > @@ -4450,8 +4450,6 @@ > timer12: timer@0 { > compatible = "ti,omap5430-timer"; > reg = <0x0 0x80>; > - clocks = <&wkupaon_clkctrl DRA7_WKUPAON_TIMER12_CLKCTRL 24>; > - clock-names = "fck"; > interrupts = <GIC_SPI 90 IRQ_TYPE_LEVEL_HIGH>; > ti,timer-alwon; > ti,timer-secure; > - Péter Texas Instruments Finland Oy, Porkkalankatu 22, 00180 Helsinki. Y-tunnus/Business ID: 0615521-4. Kotipaikka/Domicile: Helsinki