On Sun, May 12, 2019 at 10:57 PM Jerome Brunet <jbrunet@xxxxxxxxxxxx> wrote: > > MPLL_5OM (the capital letter o) should indeed be MPLL_50M (the number) > Fix this before it gets used. > > Reported-by: Martin Blumenstingl <martin.blumenstingl@xxxxxxxxxxxxxx> > Fixes: 25db146aa726 ("dt-bindings: clk: meson: add g12a periph clock controller bindings") > Signed-off-by: Jerome Brunet <jbrunet@xxxxxxxxxxxx> Reviewed-by: Martin Blumenstingl <martin.blumenstingl@xxxxxxxxxxxxxx> thank you for taking care of this issue Jerome!