Document r8a7744 specific compatible strings. No driver change is needed as the fallback compatible string "renesas,tpu" activates the right code in the driver. Signed-off-by: Biju Das <biju.das@xxxxxxxxxxxxxx> Reviewed-by: Chris Paterson <Chris.Paterson2@xxxxxxxxxxx> --- This patch is tested against next-20181004 --- Documentation/devicetree/bindings/pwm/renesas,tpu-pwm.txt | 1 + 1 file changed, 1 insertion(+) diff --git a/Documentation/devicetree/bindings/pwm/renesas,tpu-pwm.txt b/Documentation/devicetree/bindings/pwm/renesas,tpu-pwm.txt index d53a167..6d6f680 100644 --- a/Documentation/devicetree/bindings/pwm/renesas,tpu-pwm.txt +++ b/Documentation/devicetree/bindings/pwm/renesas,tpu-pwm.txt @@ -6,6 +6,7 @@ Required Properties: - "renesas,tpu-r8a73a4": for R8A73A4 (R-Mobile APE6) compatible PWM controller. - "renesas,tpu-r8a7740": for R8A7740 (R-Mobile A1) compatible PWM controller. - "renesas,tpu-r8a7743": for R8A7743 (RZ/G1M) compatible PWM controller. + - "renesas,tpu-r8a7744": for R8A7744 (RZ/G1N) compatible PWM controller. - "renesas,tpu-r8a7745": for R8A7745 (RZ/G1E) compatible PWM controller. - "renesas,tpu-r8a7790": for R8A7790 (R-Car H2) compatible PWM controller. - "renesas,tpu": for generic R-Car and RZ/G1 TPU PWM controller. -- 2.7.4