Some 3WIRE SPI devices require the host to insert a "high-impedance turn-around" essentially a clock pulse after switching the one line from output to input. This is needed to support the TPO TPG110 panel to use the 3WIRE SPI bindings. Cc: devicetree@xxxxxxxxxxxxxxx Cc: Andrzej Hajda <a.hajda@xxxxxxxxxxx> Cc: Lorenzo Bianconi <lorenzo.bianconi@xxxxxxxxxx> Signed-off-by: Linus Walleij <linus.walleij@xxxxxxxxxx> --- ChangeLog v1->v2: - Change some spelling, instert dash in high-impedance use turn-around instead of turnaround. --- Documentation/devicetree/bindings/spi/spi-bus.txt | 4 ++++ 1 file changed, 4 insertions(+) diff --git a/Documentation/devicetree/bindings/spi/spi-bus.txt b/Documentation/devicetree/bindings/spi/spi-bus.txt index 1f6e86f787ef..d0b2d88a20ee 100644 --- a/Documentation/devicetree/bindings/spi/spi-bus.txt +++ b/Documentation/devicetree/bindings/spi/spi-bus.txt @@ -70,6 +70,10 @@ All slave nodes can contain the following optional properties: - spi-cs-high - Empty property indicating device requires chip select active high. - spi-3wire - Empty property indicating device requires 3-wire mode. +- spi-3wire-high-impedance-turn-around - Empty property indicating that a + 3wire host need to insert a high-impedance turn-around + clock cycle after turning the one output line into an + input line. - spi-lsb-first - Empty property indicating device requires LSB first mode. - spi-tx-bus-width - The bus width (number of data wires) that is used for MOSI. Defaults to 1 if not present. -- 2.17.1