Document the Broadcom roboswitch Switch Register Access Block interrupt lines and additional register base addresses for port mux configuration and SGMII status/configuration registers. Signed-off-by: Florian Fainelli <f.fainelli@xxxxxxxxx> --- .../devicetree/bindings/net/dsa/b53.txt | 36 +++++++++++++++++++ 1 file changed, 36 insertions(+) diff --git a/Documentation/devicetree/bindings/net/dsa/b53.txt b/Documentation/devicetree/bindings/net/dsa/b53.txt index 1811e1972a7a..5201bc15fdd6 100644 --- a/Documentation/devicetree/bindings/net/dsa/b53.txt +++ b/Documentation/devicetree/bindings/net/dsa/b53.txt @@ -46,6 +46,42 @@ Required properties: "brcm,bcm6328-switch" "brcm,bcm6368-switch" and the mandatory "brcm,bcm63xx-switch" +Required properties for BCM585xx/586xx/88312 SoCs: + + - reg: a total of 3 register base addresses, the first one must be the + Switch Register Access block base, the second is the port 5/4 mux + configuration register and the third one is the SGMII configuration + and status register base address. + + - interrupts: a total of 13 interrupts must be specified, in the following + order: port 0-5, 7-8 link status change, then the integrated PHY interrupt, + then the timestamping interrupt and the sleep timer interrupts for ports + 5,7,8. + +Optional properties for BCM585xx/586xx/88312 SoCs: + + - reg-names: a total of 3 names matching the 3 base register address, must + be in the following order: + "srab" + "mux_config" + "sgmii_config" + + - interrupt-names: a total of 13 names matching the 13 interrupts specified + must be in the following order: + "link_state_p0" + "link_state_p1" + "link_state_p2" + "link_state_p3" + "link_state_p4" + "link_state_p5" + "link_state_p7" + "link_state_p8" + "phy" + "ts" + "imp_sleep_timer_p5" + "imp_sleep_timer_p7" + "imp_sleep_timer_p8" + See Documentation/devicetree/bindings/net/dsa/dsa.txt for a list of additional required and optional properties. -- 2.17.1