There is a HW quirk in BD71837. The shutdown sequence timings for bucks/LDOs which are enabled via register interface are changed. At PMIC poweroff the voltage for BUCK6/7 is cut immediately at the beginning of shut-down sequence. This causes LDO5/6 voltage monitoring to detect under voltage and force PMIC to emergency state instead of poweroff. Disable voltage monitoring for LDO5 and LDO6 at probe to avoid this. Signed-off-by: Matti Vaittinen <matti.vaittinen@xxxxxxxxxxxxxxxxx> --- drivers/regulator/bd71837-regulator.c | 19 +++++++++++++++++++ include/linux/mfd/rohm-bd718x7.h | 33 ++++++++++++++++++++++++++++++--- 2 files changed, 49 insertions(+), 3 deletions(-) diff --git a/drivers/regulator/bd71837-regulator.c b/drivers/regulator/bd71837-regulator.c index 0f8ac8dec3e1..a1bd8aaf4d98 100644 --- a/drivers/regulator/bd71837-regulator.c +++ b/drivers/regulator/bd71837-regulator.c @@ -569,6 +569,25 @@ static int bd71837_probe(struct platform_device *pdev) BD71837_REG_REGLOCK); } + /* + * There is a HW quirk in BD71837. The shutdown sequence timings for + * bucks/LDOs which are controlled via register interface are changed. + * At PMIC poweroff the voltage for BUCK6/7 is cut immediately at the + * beginning of shut-down sequence. As bucks 6 and 7 are parent + * supplies for LDO5 and LDO6 - this causes LDO5/6 voltage + * monitoring to errorneously detect under voltage and force PMIC to + * emergency state instead of poweroff. In order to avoid this we + * disable voltage monitoring for LDO5 and LDO6 + */ + err = regmap_update_bits(pmic->mfd->regmap, BD718XX_REG_MVRFLTMASK2, + BD718XX_LDO5_VRMON80 | BD718XX_LDO6_VRMON80, + BD718XX_LDO5_VRMON80 | BD718XX_LDO6_VRMON80); + if (err) { + dev_err(&pmic->pdev->dev, + "Failed to disable voltage monitoring\n"); + goto err; + } + for (i = 0; i < ARRAY_SIZE(pmic_regulator_inits); i++) { struct regulator_desc *desc; diff --git a/include/linux/mfd/rohm-bd718x7.h b/include/linux/mfd/rohm-bd718x7.h index a528747f8aed..e8338e5dc10b 100644 --- a/include/linux/mfd/rohm-bd718x7.h +++ b/include/linux/mfd/rohm-bd718x7.h @@ -78,9 +78,9 @@ enum { BD71837_REG_TRANS_COND0 = 0x1F, BD71837_REG_TRANS_COND1 = 0x20, BD71837_REG_VRFAULTEN = 0x21, - BD71837_REG_MVRFLTMASK0 = 0x22, - BD71837_REG_MVRFLTMASK1 = 0x23, - BD71837_REG_MVRFLTMASK2 = 0x24, + BD718XX_REG_MVRFLTMASK0 = 0x22, + BD718XX_REG_MVRFLTMASK1 = 0x23, + BD718XX_REG_MVRFLTMASK2 = 0x24, BD71837_REG_RCVCFG = 0x25, BD71837_REG_RCVNUM = 0x26, BD71837_REG_PWRONCONFIG0 = 0x27, @@ -159,6 +159,33 @@ enum { #define BUCK8_MASK 0x3F #define BUCK8_DEFAULT 0x1E +/* BD718XX Voltage monitoring masks */ +#define BD718XX_BUCK1_VRMON80 0x1 +#define BD718XX_BUCK1_VRMON130 0x2 +#define BD718XX_BUCK2_VRMON80 0x4 +#define BD718XX_BUCK2_VRMON130 0x8 +#define BD718XX_1ST_NODVS_BUCK_VRMON80 0x1 +#define BD718XX_1ST_NODVS_BUCK_VRMON130 0x2 +#define BD718XX_2ND_NODVS_BUCK_VRMON80 0x4 +#define BD718XX_2ND_NODVS_BUCK_VRMON130 0x8 +#define BD718XX_3RD_NODVS_BUCK_VRMON80 0x10 +#define BD718XX_3RD_NODVS_BUCK_VRMON130 0x20 +#define BD718XX_4TH_NODVS_BUCK_VRMON80 0x40 +#define BD718XX_4TH_NODVS_BUCK_VRMON130 0x80 +#define BD718XX_LDO1_VRMON80 0x1 +#define BD718XX_LDO2_VRMON80 0x2 +#define BD718XX_LDO3_VRMON80 0x4 +#define BD718XX_LDO4_VRMON80 0x8 +#define BD718XX_LDO5_VRMON80 0x10 +#define BD718XX_LDO6_VRMON80 0x20 + +/* BD71837 specific voltage monitoring masks */ +#define BD71837_BUCK3_VRMON80 0x10 +#define BD71837_BUCK3_VRMON130 0x20 +#define BD71837_BUCK4_VRMON80 0x40 +#define BD71837_BUCK4_VRMON130 0x80 +#define BD71837_LDO7_VRMON80 0x40 + /* BD71837_REG_IRQ bits */ #define IRQ_SWRST 0x40 #define IRQ_PWRON_S 0x20 -- 2.14.3