Hi Krzysztof, On 17 July 2018 at 17:58, Krzysztof Kozlowski <krzk@xxxxxxxxxx> wrote: > On 17 July 2018 at 12:12, Anand Moon <linux.amoon@xxxxxxxxx> wrote: >> e-fuse range min~max range is 16~76. if e-fuse value is out of > > s/e-fuse/Fuse/ > s/if/If/ > > Can you share the sources confirming that fuse values are between 16 and 76? > Below is my patch : https://github.com/hardkernel/linux/commit/52c4c9b295930bc53b215d38e274aeb0780917f1 e-Fuse range min/max values are from exynos5422 user manual. Best Regards -Anand -- To unsubscribe from this list: send the line "unsubscribe devicetree" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html