e-fuse range min~max range is 16~76. if e-fuse value is out of this range, then thermal sensor may not sense thermal data properly. CC: Bartlomiej Zolnierkiewicz <b.zolnierkie@xxxxxxxxxxx> Signed-off-by: Anand Moon <linux.amoon@xxxxxxxxx> --- drivers/thermal/samsung/exynos_tmu.c | 10 ++++++---- 1 file changed, 6 insertions(+), 4 deletions(-) diff --git a/drivers/thermal/samsung/exynos_tmu.c b/drivers/thermal/samsung/exynos_tmu.c index 4a2733c..6481d91 100644 --- a/drivers/thermal/samsung/exynos_tmu.c +++ b/drivers/thermal/samsung/exynos_tmu.c @@ -940,11 +940,13 @@ static int exynos_map_dt_data(struct platform_device *pdev) data->reference_voltage = 16; data->efuse_value = 55; if (data->soc != SOC_ARCH_EXYNOS5420 && - data->soc != SOC_ARCH_EXYNOS5420_TRIMINFO) + data->soc != SOC_ARCH_EXYNOS5420_TRIMINFO) { + data->min_efuse_value = 16; + data->max_efuse_value = 76; + } else { data->min_efuse_value = 40; - else - data->min_efuse_value = 0; - data->max_efuse_value = 100; + data->max_efuse_value = 100; + } break; case SOC_ARCH_EXYNOS5433: data->tmu_set_trip_temp = exynos5433_tmu_set_trip_temp; -- 2.7.4 -- To unsubscribe from this list: send the line "unsubscribe devicetree" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html