Hi Jacopo,
Hope your fine.
Thanks for the review.
On Wed 04 Jul 2018 at 09:58, jacopo mondi wrote:
Hi Rui,
sorry, I'm a bit late, you're already at v7 and I don't want
to
slow down inclusion with a few minor comments.
Please bear with me and see below...
On Tue, Jul 03, 2018 at 03:08:02PM +0100, Rui Miguel Silva
wrote:
Add device tree binding documentation for the OV2680 camera
sensor.
CC: devicetree@xxxxxxxxxxxxxxx
Signed-off-by: Rui Miguel Silva <rui.silva@xxxxxxxxxx>
---
.../devicetree/bindings/media/i2c/ov2680.txt | 46
+++++++++++++++++++
1 file changed, 46 insertions(+)
create mode 100644
Documentation/devicetree/bindings/media/i2c/ov2680.txt
diff --git
a/Documentation/devicetree/bindings/media/i2c/ov2680.txt
b/Documentation/devicetree/bindings/media/i2c/ov2680.txt
new file mode 100644
index 000000000000..11e925ed9dad
--- /dev/null
+++ b/Documentation/devicetree/bindings/media/i2c/ov2680.txt
@@ -0,0 +1,46 @@
+* Omnivision OV2680 MIPI CSI-2 sensor
+
+Required Properties:
+- compatible: should be "ovti,ov2680".
+- clocks: reference to the xvclk input clock.
+- clock-names: should be "xvclk".
Having a single clock source I think you can omit 'clock-names'
(or at
least not marking it as required)
yeah, I see you point, but really all other OV sensors share this
and
the bellow clock/data-lanes properties as required, I will let Rob
or
Sakari take a call in this one.
---
Cheers,
Rui
+- DOVDD-supply: Digital I/O voltage supply.
+- DVDD-supply: Digital core voltage supply.
+- AVDD-supply: Analog voltage supply.
+
+Optional Properties:
+- reset-gpios: reference to the GPIO connected to the
powerdown/reset pin,
+ if any. This is an active low signal to the
OV2680.
+
+The device node must contain one 'port' child node for its
digital output
+video port, and this port must have a single endpoint in
accordance with
+ the video interface bindings defined in
+Documentation/devicetree/bindings/media/video-interfaces.txt.
+
+Endpoint node required properties for CSI-2 connection are:
+- remote-endpoint: a phandle to the bus receiver's endpoint
node.
+- clock-lanes: should be set to <0> (clock lane on hardware
lane 0).
+- data-lanes: should be set to <1> (one CSI-2 lane supported).
What is the value of marking as required two properties which
can only have
default values (the sensor does not support clock on different
lanes,
nor it supports more than 1 data lane) ?
Thanks
j
+
+Example:
+
+&i2c2 {
+ ov2680: camera-sensor@36 {
+ compatible = "ovti,ov2680";
+ reg = <0x36>;
+ clocks = <&osc>;
+ clock-names = "xvclk";
+ reset-gpios = <&gpio1 3 GPIO_ACTIVE_LOW>;
+ DOVDD-supply = <&sw2_reg>;
+ DVDD-supply = <&sw2_reg>;
+ AVDD-supply = <®_peri_3p15v>;
+
+ port {
+ ov2680_to_mipi: endpoint {
+ remote-endpoint =
<&mipi_from_sensor>;
+ clock-lanes = <0>;
+ data-lanes = <1>;
+ };
+ };
+ };
+};
--
2.18.0
--
To unsubscribe from this list: send the line "unsubscribe devicetree" in
the body of a message to majordomo@xxxxxxxxxxxxxxx