Am Freitag, 25. Mai 2018, 12:31:50 CEST schrieb Viresh Kumar: > The cooling device properties, like "#cooling-cells" and > "dynamic-power-coefficient", should either be present for all the CPUs > of a cluster or none. If these are present only for a subset of CPUs of > a cluster then things will start falling apart as soon as the CPUs are > brought online in a different order. For example, this will happen > because the operating system looks for such properties in the CPU node > it is trying to bring up, so that it can register a cooling device. > > Add such missing properties. > > Signed-off-by: Viresh Kumar <viresh.kumar@xxxxxxxxxx> applied for 4.19 Thanks Heiko -- To unsubscribe from this list: send the line "unsubscribe devicetree" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html