The cooling device properties, like "#cooling-cells" and "dynamic-power-coefficient", should either be present for all the CPUs of a cluster or none. If these are present only for a subset of CPUs of a cluster then things will start falling apart as soon as the CPUs are brought online in a different order. For example, this will happen because the operating system looks for such properties in the CPU node it is trying to bring up, so that it can register a cooling device. Add such missing properties. Signed-off-by: Viresh Kumar <viresh.kumar@xxxxxxxxxx> --- arch/arm/boot/dts/rk322x.dtsi | 3 +++ 1 file changed, 3 insertions(+) diff --git a/arch/arm/boot/dts/rk322x.dtsi b/arch/arm/boot/dts/rk322x.dtsi index be80e9a2c9af..ef414e39bf3a 100644 --- a/arch/arm/boot/dts/rk322x.dtsi +++ b/arch/arm/boot/dts/rk322x.dtsi @@ -80,6 +80,7 @@ reg = <0xf01>; resets = <&cru SRST_CORE1>; operating-points-v2 = <&cpu0_opp_table>; + #cooling-cells = <2>; /* min followed by max */ enable-method = "psci"; }; @@ -89,6 +90,7 @@ reg = <0xf02>; resets = <&cru SRST_CORE2>; operating-points-v2 = <&cpu0_opp_table>; + #cooling-cells = <2>; /* min followed by max */ enable-method = "psci"; }; @@ -98,6 +100,7 @@ reg = <0xf03>; resets = <&cru SRST_CORE3>; operating-points-v2 = <&cpu0_opp_table>; + #cooling-cells = <2>; /* min followed by max */ enable-method = "psci"; }; }; -- 2.15.0.194.g9af6a3dea062 -- To unsubscribe from this list: send the line "unsubscribe devicetree" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html