On Wed, Jun 06, 2018 at 12:02:20AM +0800, Chen-Yu Tsai wrote: > On Tue, Jun 5, 2018 at 3:11 PM, Maxime Ripard <maxime.ripard@xxxxxxxxxxx> wrote: > > On Tue, Jun 05, 2018 at 10:17:49AM +0530, Viresh Kumar wrote: > >> The cooling device properties, like "#cooling-cells" and > >> "dynamic-power-coefficient", should either be present for all the CPUs > >> of a cluster or none. If these are present only for a subset of CPUs of > >> a cluster then things will start falling apart as soon as the CPUs are > >> brought online in a different order. For example, this will happen > >> because the operating system looks for such properties in the CPU node > >> it is trying to bring up, so that it can register a cooling device. > >> > >> Add such missing properties. > >> > >> Fix other missing properties (clocks, OPP, clock latency) as well to > >> make it all work. > >> > >> Signed-off-by: Viresh Kumar <viresh.kumar@xxxxxxxxxx> > > > > Applied both, thanks! > > Please fix the "ARM" prefix when applying. :) Done, thanks for the reminder :) Maxime -- Maxime Ripard, Bootlin (formerly Free Electrons) Embedded Linux and Kernel engineering https://bootlin.com