On Tue, Jun 05, 2018 at 10:17:49AM +0530, Viresh Kumar wrote: > The cooling device properties, like "#cooling-cells" and > "dynamic-power-coefficient", should either be present for all the CPUs > of a cluster or none. If these are present only for a subset of CPUs of > a cluster then things will start falling apart as soon as the CPUs are > brought online in a different order. For example, this will happen > because the operating system looks for such properties in the CPU node > it is trying to bring up, so that it can register a cooling device. > > Add such missing properties. > > Fix other missing properties (clocks, OPP, clock latency) as well to > make it all work. > > Signed-off-by: Viresh Kumar <viresh.kumar@xxxxxxxxxx> Applied both, thanks! Maxime -- Maxime Ripard, Bootlin (formerly Free Electrons) Embedded Linux and Kernel engineering https://bootlin.com
Attachment:
signature.asc
Description: PGP signature