Hi Yisheng,
On 4/11/2018 6:52 AM, Yisheng Xie wrote:
Hi Tomasz,
On 2018/4/10 21:14, Tomasz Figa wrote:
Hi Yisheng,
Sorry, I think we missed your question here.
On Wed, Mar 28, 2018 at 3:12 PM Yisheng Xie <xieyisheng1@xxxxxxxxxx> wrote:
Hi Vivek,
On 2018/3/28 12:37, Vivek Gautam wrote:
Hi Yisheng
On 3/28/2018 6:54 AM, Yisheng Xie wrote:
Hi Vivek,
On 2018/3/13 16:55, Vivek Gautam wrote:
+- power-domains: Specifiers for power domains required to be
powered on for
+ the SMMU to operate, as per generic power domain
bindings.
+
In this patchset, power-domains is not used right? And you just do the
clock gating,
but not power gating, right?
We are handling the power-domains too. Please see the example in this
binding doc.
I see, but I do not find the point in code of these patchset, do you mean
PMIC(e.g mmcc)
will gate the power domain of SMMU(e.g. MDSS_GDSC of mmcc) when PMIC
suspend?
If respective SoC power domains is registered as a standard genpd PM
domain, then the runtime PM subsystem will take care of power domain
control at runtime suspend and resume.
Get it, thanks for your explain, I should have learned about this.
Sorry, i missed your subsequent question, and Tomasz has explained it now.
Let me know if you have further questions.
regards
Vivek
Thanks
Yisheng
Best regards,
Tomasz
.
--
To unsubscribe from this list: send the line "unsubscribe linux-arm-msm" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html
--
To unsubscribe from this list: send the line "unsubscribe devicetree" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html