Add documentation about how to properly use the Ingenic TCU (Timer/Counter Unit) drivers from devicetree. Signed-off-by: Paul Cercueil <paul@xxxxxxxxxxxxxxx> --- .../bindings/clock/ingenic,tcu-clocks.txt | 42 ++++++++++++++++ .../bindings/interrupt-controller/ingenic,tcu.txt | 39 +++++++++++++++ .../devicetree/bindings/mfd/ingenic,tcu.txt | 56 ++++++++++++++++++++++ .../devicetree/bindings/timer/ingenic,tcu.txt | 41 ++++++++++++++++ 4 files changed, 178 insertions(+) create mode 100644 Documentation/devicetree/bindings/clock/ingenic,tcu-clocks.txt create mode 100644 Documentation/devicetree/bindings/interrupt-controller/ingenic,tcu.txt create mode 100644 Documentation/devicetree/bindings/mfd/ingenic,tcu.txt create mode 100644 Documentation/devicetree/bindings/timer/ingenic,tcu.txt v4: New patch in this series. Corresponds to V2 patches 3-4-5 with added content. diff --git a/Documentation/devicetree/bindings/clock/ingenic,tcu-clocks.txt b/Documentation/devicetree/bindings/clock/ingenic,tcu-clocks.txt new file mode 100644 index 000000000000..471d27078599 --- /dev/null +++ b/Documentation/devicetree/bindings/clock/ingenic,tcu-clocks.txt @@ -0,0 +1,42 @@ +Ingenic SoC TCU binding + +The TCU is the Timer/Counter Unit present in all Ingenic SoCs. It features 8 +channels, each one having its own clock, that can be started and stopped, +reparented, and reclocked. + +Required properties: +- compatible : One of: + * ingenic,jz4740-tcu-clocks, + * ingenic,jz4770-tcu-clocks, + * ingenic,jz4780-tcu-clocks. +- clocks : List of phandle & clock specifiers for clocks external to the TCU. + The "pclk", "rtc" and "ext" clocks should be provided. +- clock-names : List of name strings for the external clocks. +- #clock-cells: Should be 1. + Clock consumers specify this argument to identify a clock. The valid values + may be found in <dt-bindings/clock/ingenic,tcu.h>. + +Example: + +/ { + tcu: mfd@10002000 { + compatible = "ingenic,tcu", "simple-mfd", "syscon"; + reg = <0x10002000 0x1000>; + #address-cells = <1>; + #size-cells = <1>; + ranges = <0x0 0x10002000 0x1000>; + + tcu_clk: clocks@10 { + compatible = "ingenic,jz4740-tcu-clocks"; + reg = <0x10 0xff0>; + + clocks = <&ext>, <&rtc>, <&pclk>; + clock-names = "ext", "rtc", "pclk"; + + #clock-cells = <1>; + }; + }; +}; + +For information about the top-level "ingenic,tcu" compatible node and other +children nodes, see Documentation/devicetree/bindings/mfd/ingenic,tcu.txt. diff --git a/Documentation/devicetree/bindings/interrupt-controller/ingenic,tcu.txt b/Documentation/devicetree/bindings/interrupt-controller/ingenic,tcu.txt new file mode 100644 index 000000000000..7f3af2da77cd --- /dev/null +++ b/Documentation/devicetree/bindings/interrupt-controller/ingenic,tcu.txt @@ -0,0 +1,39 @@ +Ingenic SoCs Timer/Counter Unit Interrupt Controller + +Required properties: + +- compatible : should be "ingenic,<socname>-tcu-intc". Valid strings are: + * ingenic,jz4740-tcu-intc + * ingenic,jz4770-tcu-intc + * ingenic,jz4780-tcu-intc +- interrupt-controller : Identifies the node as an interrupt controller +- #interrupt-cells : Specifies the number of cells needed to encode an + interrupt source. The value shall be 1. +- interrupt-parent : phandle of the interrupt controller. +- interrupts : Specifies the interrupt the controller is connected to. + +Example: + +/ { + tcu: mfd@10002000 { + compatible = "ingenic,tcu", "simple-mfd", "syscon"; + reg = <0x10002000 0x1000>; + #address-cells = <1>; + #size-cells = <1>; + ranges = <0x0 0x10002000 0x1000>; + + tcu_irq: interrupt-controller@20 { + compatible = "ingenic,jz4740-tcu-intc"; + reg = <0x20 0x20>; + + interrupt-controller; + #interrupt-cells = <1>; + + interrupt-parent = <&intc>; + interrupts = <15>; + }; + }; +}; + +For information about the top-level "ingenic,tcu" compatible node and other +children nodes, see Documentation/devicetree/bindings/mfd/ingenic,tcu.txt. diff --git a/Documentation/devicetree/bindings/mfd/ingenic,tcu.txt b/Documentation/devicetree/bindings/mfd/ingenic,tcu.txt new file mode 100644 index 000000000000..5742c3f21550 --- /dev/null +++ b/Documentation/devicetree/bindings/mfd/ingenic,tcu.txt @@ -0,0 +1,56 @@ +Ingenic JZ47xx SoCs Timer/Counter Unit devicetree bindings +---------------------------------------------------------- + +For a description of the TCU hardware and drivers, have a look at +Documentation/mips/ingenic-tcu.txt. + +The TCU is implemented as a parent node, whose role is to create the +regmap, and child nodes for the various drivers listed in the aforementioned +document. + +Required properties: + +- compatible: must be "ingenic,tcu", "simple-mfd", "syscon"; +- reg: Should be the offset/length value corresponding to the TCU registers +- #address-cells: Should be <1>; +- #size-cells: Should be <1>; +- ranges: Should be one range for the full TCU registers area + +Accepted children nodes: +- Documentation/devicetree/bindings/interrupt-controller/ingenic,tcu.txt +- Documentation/devicetree/bindings/clock/ingenic,tcu-clocks.txt +- Documentation/devicetree/bindings/timer/ingenic,tcu.txt + + +Example: + +/ { + tcu: mfd@10002000 { + compatible = "ingenic,tcu", "simple-mfd", "syscon"; + reg = <0x10002000 0x1000>; + #address-cells = <1>; + #size-cells = <1>; + ranges = <0x0 0x10002000 0x1000>; + + tcu_irq: interrupt-controller@20 { + compatible = "ingenic,jz4740-tcu-intc"; + reg = <0x20 0x20>; + ... + }; + + tcu_clk: clocks@10 { + compatible = "ingenic,jz4740-tcu-clocks"; + reg = <0x10 0xff0>; + ... + }; + + tcu_timer: timer@10 { + compatible = "ingenic,jz4740-tcu"; + reg = <0x10 0xff0>; + ... + }; + }; +}; + +For more information about the children node, refer to the documents listed +above in the "Accepted children nodes" section. diff --git a/Documentation/devicetree/bindings/timer/ingenic,tcu.txt b/Documentation/devicetree/bindings/timer/ingenic,tcu.txt new file mode 100644 index 000000000000..f910b7e96783 --- /dev/null +++ b/Documentation/devicetree/bindings/timer/ingenic,tcu.txt @@ -0,0 +1,41 @@ +Ingenic JZ47xx SoCs Timer/Counter Unit driver +--------------------------------------------- + +Required properties: + +- compatible : should be "ingenic,<socname>-tcu". Valid strings are: + * ingenic,jz4740-tcu + * ingenic,jz4770-tcu + * ingenic,jz4780-tcu +- interrupt-parent : phandle of the TCU interrupt controller. +- interrupts : Specifies the interrupts the controller is connected to. +- clocks : List of phandle & clock specifiers for the TCU clocks. +- clock-names : List of name strings for the TCU clocks. + +Example: + +/ { + tcu: mfd@10002000 { + compatible = "ingenic,tcu", "simple-mfd", "syscon"; + reg = <0x10002000 0x1000>; + #address-cells = <1>; + #size-cells = <1>; + ranges = <0x0 0x10002000 0x1000>; + + tcu_timer: timer@10 { + compatible = "ingenic,jz4740-tcu"; + reg = <0x10 0xff0>; + + clocks = <&tcu_clk 0>, <&tcu_clk 1>, <&tcu_clk 2>, <&tcu_clk 3>, + <&tcu_clk 4>, <&tcu_clk 5>, <&tcu_clk 6>, <&tcu_clk 7>; + clock-names = "timer0", "timer1", "timer2", "timer3", + "timer4", "timer5", "timer6", "timer7"; + + interrupt-parent = <&tcu_irq>; + interrupts = <0 1 2 3 4 5 6 7>; + }; + }; +}; + +For information about the top-level "ingenic,tcu" compatible node and other +children nodes, see Documentation/devicetree/bindings/mfd/ingenic,tcu.txt. -- 2.11.0 -- To unsubscribe from this list: send the line "unsubscribe devicetree" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html