From: Baruch Siach <baruch@xxxxxxxxxx> The AP806 component is integrated in the Armada 8k and 7k lines of processors. The thermal sensor sample field on the status register is a signed value. Extend armada_get_temp() to handle signed values. Signed-off-by: Baruch Siach <baruch@xxxxxxxxxx> Signed-off-by: Miquel Raynal <miquel.raynal@xxxxxxxxxxxxxxxxxx> --- drivers/thermal/armada_thermal.c | 51 ++++++++++++++++++++++++++++++++++++++-- 1 file changed, 49 insertions(+), 2 deletions(-) diff --git a/drivers/thermal/armada_thermal.c b/drivers/thermal/armada_thermal.c index e5b184cee79b..279d01937bb8 100644 --- a/drivers/thermal/armada_thermal.c +++ b/drivers/thermal/armada_thermal.c @@ -47,6 +47,11 @@ #define CONTROL0_OFFSET 0x0 #define CONTROL1_OFFSET 0x4 +/* TSEN refers to the temperature sensors within the AP */ +#define CONTROL0_TSEN_START BIT(0) +#define CONTROL0_TSEN_RESET BIT(1) +#define CONTROL0_TSEN_ENABLE BIT(2) + struct armada_thermal_data; /* Marvell EBU Thermal Sensor Dev Structure */ @@ -70,6 +75,7 @@ struct armada_thermal_data { unsigned long coef_m; unsigned long coef_div; bool inverted; + bool signed_sample; /* Register shift and mask to access the sensor temperature */ unsigned int temp_shift; @@ -154,6 +160,24 @@ static void armada380_init_sensor(struct platform_device *pdev, } } +static void armada_ap806_init_sensor(struct platform_device *pdev, + struct armada_thermal_priv *priv) +{ + u32 reg; + + if (!priv->control0) { + dev_err(&pdev->dev, + "Cannot access to control0 (control LSB) register\n"); + return; + } + + reg = readl_relaxed(priv->control0); + reg &= ~CONTROL0_TSEN_RESET; + reg |= CONTROL0_TSEN_START | CONTROL0_TSEN_ENABLE; + writel(reg, priv->control0); + msleep(10); +} + static bool armada_is_valid(struct armada_thermal_priv *priv) { u32 reg = readl_relaxed(priv->status); @@ -167,6 +191,7 @@ static int armada_get_temp(struct thermal_zone_device *thermal, struct armada_thermal_priv *priv = thermal->devdata; u32 reg; unsigned long m, b, div; + int sample; /* Valid check */ if (priv->data->is_valid && !priv->data->is_valid(priv)) { @@ -177,6 +202,11 @@ static int armada_get_temp(struct thermal_zone_device *thermal, reg = readl_relaxed(priv->status); reg = (reg >> priv->data->temp_shift) & priv->data->temp_mask; + if (priv->data->signed_sample) + /* The most significant bit is the sign bit */ + sample = sign_extend32(reg, fls(priv->data->temp_mask) - 1); + else + sample = reg; /* Get formula coeficients */ b = priv->data->coef_b; @@ -184,9 +214,9 @@ static int armada_get_temp(struct thermal_zone_device *thermal, div = priv->data->coef_div; if (priv->data->inverted) - *temp = ((m * reg) - b) / div; + *temp = ((m * sample) - b) / div; else - *temp = (b - (m * reg)) / div; + *temp = (b - (m * sample)) / div; return 0; } @@ -237,6 +267,19 @@ static const struct armada_thermal_data armada380_data = { .inverted = true, }; +static const struct armada_thermal_data armada_ap806_data = { + .is_valid = armada_is_valid, + .init_sensor = armada_ap806_init_sensor, + .is_valid_bit = BIT(16), + .temp_shift = 0, + .temp_mask = 0x3ff, + .coef_b = -150000, + .coef_m = 423UL, + .coef_div = 1, + .inverted = true, + .signed_sample = true, +}; + static const struct of_device_id armada_thermal_id_table[] = { { .compatible = "marvell,armadaxp-thermal", @@ -255,6 +298,10 @@ static const struct of_device_id armada_thermal_id_table[] = { .data = &armada380_data, }, { + .compatible = "marvell,armada-ap806-thermal", + .data = &armada_ap806_data, + }, + { /* sentinel */ }, }; -- 2.11.0 -- To unsubscribe from this list: send the line "unsubscribe devicetree" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html