On 30/05/17 10:05, Carlo Caione wrote: > From: Carlo Caione <carlo@xxxxxxxxxxxx> > > The implementation details for SCPI seems to suggest that the sensor > readings must be reported by SCP using a well defined scale > (millidegree Celsius for temperature, millivolts for voltage, > milliamperes for current, microwatts for power and microjoules for > energy). > > This is also important for the interaction with other subsystems: for > example both the thermal sub-system and the hwmon sysfs interface expect > the temperature expressed in millidegree Celsius. > > Unfortunately since this behaviour is dependent on the firmware > implementation there are cases where the sensor readings are reported > using a different scale. For example in the Amlogic SoCs the > temperature is reported in degree and not millidegree Celsius. > > To take into account this discrepancy and fixup the values reported by > SCP a new compatible 'amlogic,meson-gxbb-scpi-sensors' is introduced and > used in this patch by the scpi-hwmon driver to convert the sensor > readings to the expected scale. > Looks good to me Acked-by: Sudeep Holla <sudeep.holla@xxxxxxx> -- Regards, Sudeep -- To unsubscribe from this list: send the line "unsubscribe devicetree" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html