On 06/03/2016 04:02 AM, Rob Herring wrote: >> Optional properties: >> - reset-gpios : contains a list of GPIO specifiers. The reset GPIOs are asserted >> @@ -16,6 +22,7 @@ Optional properties: >> See ../clocks/clock-bindings.txt for details. >> - clock-names : Must include the following entry: >> "ext_clock" (External clock provided to the card). >> +- ext-supply : External regulator supply > > What happens when there are 2 supplies? > > I'd prefer the name not be genericish and use the real supply names. > Then the power seq code should just turn on all supplies it finds. If > the order or timing to turn on matters, then sorry, no generic sequence. I think the generic part for regulators might be a problem. Regulator API requires a name for the supply... it cannot get "something" or "everything". The driver could attach itself to any kind of node (where power-sequence property exists) so the supply name depends on the bindings of device (not bindings of power sequence driver). The power sequence driver could however iterate over child properties and get the names of all supplies. It is a little bit ugly... Best regards, Krzysztof -- To unsubscribe from this list: send the line "unsubscribe devicetree" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html