Document the pwm-dutycycle-unit and pwm-dutycycle-range properties. Signed-off-by: Boris Brezillon <boris.brezillon@xxxxxxxxxxxxxxxxxx> --- .../devicetree/bindings/regulator/pwm-regulator.txt | 12 ++++++++++++ 1 file changed, 12 insertions(+) diff --git a/Documentation/devicetree/bindings/regulator/pwm-regulator.txt b/Documentation/devicetree/bindings/regulator/pwm-regulator.txt index ed936f0..5303235 100644 --- a/Documentation/devicetree/bindings/regulator/pwm-regulator.txt +++ b/Documentation/devicetree/bindings/regulator/pwm-regulator.txt @@ -34,6 +34,18 @@ Only required for Voltage Table Mode: First cell is voltage in microvolts (uV) Second cell is duty-cycle in percent (%) +Optional properties for Continuous mode: +- pwm-dutycycle-unit: Integer value encoding the dutycycle unit. If not + defined, <100> is assumed, meaning that + pwm-dutycycle-range contains values expressed in + percent. + +- pwm-dutycycle-range: Should contain 2 entries. The first entry is encoding + the dutycycle for regulator-min-microvolt and the + second one the dutycycle for regulator-max-microvolt. + Dutycyle values are expressed in pwm-dutycycle-unit. + If not defined, <0 100> is assumed. + NB: To be clear, if voltage-table is provided, then the device will be used in Voltage Table Mode. If no voltage-table is provided, then the device will be used in Continuous Voltage Mode. -- 2.7.4 -- To unsubscribe from this list: send the line "unsubscribe devicetree" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html