Hi Ivo, On Sat, Apr 16, 2016 at 09:37:23AM +0300, Ivaylo Dimitrov wrote: > Without that, regulators are left in the mode last set by the bootloader or > by the kernel the device was rebooted from. This leads to various problems > like non-working peripherals. > > Signed-off-by: Ivaylo Dimitrov <ivo.g.dimitrov.75@xxxxxxxxx> > --- > arch/arm/boot/dts/omap3-n900.dts | 9 +++++++++ > 1 file changed, 9 insertions(+) > > diff --git a/arch/arm/boot/dts/omap3-n900.dts b/arch/arm/boot/dts/omap3-n900.dts > index b3c26a9..1bb36e2 100644 > --- a/arch/arm/boot/dts/omap3-n900.dts > +++ b/arch/arm/boot/dts/omap3-n900.dts > @@ -329,6 +329,7 @@ > regulator-name = "V28"; > regulator-min-microvolt = <2800000>; > regulator-max-microvolt = <2800000>; > + regulator-initial-mode = <0x0e>; > regulator-always-on; /* due to battery cover sensor */ > }; I think this should either get an additional comment like /* MODE_NORMAL */ or implemented using a define and a TWL4030_REGULATOR_MODE_NORMAL constant to keep the *.dts easily readable. -- Sebastian
Attachment:
signature.asc
Description: PGP signature