On Fri, Apr 01, 2016 at 12:29:05AM +0530, Laxman Dewangan wrote: > On Friday 01 April 2016 12:29 AM, Mark Brown wrote: > /** > Here is the case, > PMIC supports 2 ramp time configurations 5mv/us and 100mV/us. This is This looks like a typo given a lot of the other content and the fact that this is a concern. > But here is the stuff without typo ;-) > Device supports 5mV/us and 100mV/us which is not in observed value. So why doesn't the device end up configuring 100mV/us when asked for 50mv/us? That's reasonably expected - the configured ramp rate is a maximum rate given that this is used to limit inrush current.