At probe time, when the clock driver is not yet initialized, the external clock of the kirkwood sound device will not be usable. This patch fixes this problem defering the device probe. Signed-off-by: Jean-Francois Moine <moinejf@xxxxxxx> --- sound/soc/kirkwood/kirkwood-i2s.c | 5 ++++- 1 file changed, 4 insertions(+), 1 deletion(-) diff --git a/sound/soc/kirkwood/kirkwood-i2s.c b/sound/soc/kirkwood/kirkwood-i2s.c index 0f3d73d..14f32d9 100644 --- a/sound/soc/kirkwood/kirkwood-i2s.c +++ b/sound/soc/kirkwood/kirkwood-i2s.c @@ -496,7 +496,10 @@ static int kirkwood_i2s_dev_probe(struct platform_device *pdev) return err; priv->extclk = devm_clk_get(&pdev->dev, "extclk"); - if (!IS_ERR(priv->extclk)) { + if (IS_ERR(priv->extclk)) { + if (np && of_property_match_string(np, "clock-names", "extclk") >= 0) + return -EPROBE_DEFER; + } else { if (priv->extclk == priv->clk) { devm_clk_put(&pdev->dev, priv->extclk); priv->extclk = ERR_PTR(-EINVAL); -- Ken ar c'hentañ | ** Breizh ha Linux atav! ** Jef | http://moinejf.free.fr/ -- To unsubscribe from this list: send the line "unsubscribe devicetree" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html