Re: clusvcadm

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On 07/05/14 06:41 PM, Paras pradhan wrote:
Yes the fencing failed because of the network issues and I had to reboot
one of the manually and it came back normal. But now I am seeing this
DLM is blocked.

Then this is why you're stuck. RGmanager, gfs2 and clvmd all use DLM and they will block when DLM blocks. When a fence is called, fenced informs dlm, and dlm remains blocked until fenced tells dlm that it's safe to recover.

If you are *certain* that the one nodes is powered off (or rebooted and cman/rgmanager was not started), you can run 'fence_ack_manual' to tell fenced that the node was fenced. Be very careful with this; improper use can corrupt your cluster.

Alternatively, restart all nodes.

--
Digimer
Papers and Projects: https://alteeve.ca/w/
What if the cure for cancer is trapped in the mind of a person without access to education?

--
Linux-cluster mailing list
Linux-cluster@xxxxxxxxxx
https://www.redhat.com/mailman/listinfo/linux-cluster




[Index of Archives]     [Corosync Cluster Engine]     [GFS]     [Linux Virtualization]     [Centos Virtualization]     [Centos]     [Linux RAID]     [Fedora Users]     [Fedora SELinux]     [Big List of Linux Books]     [Yosemite Camping]

  Powered by Linux