Ok I see you are using fence_ilo but I don't see a messages snip.  The messages snip will tell us exactly what is going on, there isn't much I can do without it.  You may want to try running:

>From node 2:
# fence_node rhel-cluster-node1.mgmt.local

>From node 1:
# fence_node rhel-cluster-node2.mgmt.local

This should cause your nodes to get rebooted, if it doesn't then there is a problem with your fencing config.  A snip of your messages file from one of these events would help out here.

-Ben






----- "Wahyu Darmawan" <wahyu@xxxxxxxxxxxxxx> wrote:

> Hi Ben,
> Here is my cluster.conf. Need your help please.
> 
> 
> <?xml version="1.0"?>
> <cluster alias="PORTAL_WORLD" config_version="32" name="PORTAL_WORLD">
> 	<fence_daemon clean_start="0" post_fail_delay="0"
> post_join_delay="3"/>
> 	<clusternodes>
> 		<clusternode name="rhel-cluster-node1.mgmt.local" nodeid="1"
> votes="1">
> 			<fence>
> 				<method name="1">
> 					<device name="NODE1-ILO"/>
> 				</method>
> 			</fence>
> 		</clusternode>
> 		<clusternode name="rhel-cluster-node2.mgmt.local" nodeid="2"
> votes="1">
> 			<fence>
> 				<method name="1">
> 					<device name="NODE2-ILO"/>
> 				</method>
> 			</fence>
> 		</clusternode>
> 	</clusternodes>
> 	<quorumd device="/dev/sdf1" interval="3" label="quorum_disk1"
> tko="23" votes="2">
> 		<heuristic interval="2" program="ping 10.4.0.1 -c1 -t1" score="1"/>
> 	</quorumd>
> 	<cman expected_votes="1" two_node="1"/>
> 	<fencedevices>
> 		<fencedevice agent="fence_ilo" hostname="ilo-node2"
> login="Administrator" name="NODE2-ILO" passwd="password"/>
> 		<fencedevice agent="fence_ilo" hostname="ilo-node1"
> login="Administrator" name="NODE1-ILO" passwd="password"/>
> 	</fencedevices>
> 	<rm>
> 		<failoverdomains>
> 			<failoverdomain name="Failover" nofailback="1" ordered="0"
> restricted="0">
> 				<failoverdomainnode name="rhel-cluster-node2.mgmt.local"
> priority="1"/>
> 				<failoverdomainnode name="rhel-cluster-node1.mgmt.local"
> priority="1"/>
> 			</failoverdomain>
> 		</failoverdomains>
> 		<resources>
> 			<ip address="10.4.1.103" monitor_link="1"/>
> 		</resources>
> 		<service autostart="1" domain="Failover" exclusive="0"
> name="IP_Virtual" recovery="relocate">
> 			<ip ref="10.4.1.103"/>
> 		</service>
> 	</rm>
> </cluster>
> 
> Many thanks,
> Wahyu
> 
> -----Original Message-----
> From: linux-cluster-bounces@xxxxxxxxxx
> [mailto:linux-cluster-bounces@xxxxxxxxxx] On Behalf Of Ben Turner
> Sent: Thursday, October 28, 2010 12:18 AM
> To: linux clustering
> Subject: Re:  Fence Issue on BL 460C G6
> 
> My guess is there is a problem with fencing.  Are you running
> fence_ilo with an HP blade?   Iirc the iLOs on the blades have a
> different CLI, I don't think fence_ilo will work with them.  What do
> you see in the messages files during these events?  If you see failed
> fence messages you may want to look into using fence_ipmilan:
> 
> http://sources.redhat.com/cluster/wiki/IPMI_FencingConfig
> 
> If you post a snip of your messages file from this event and your
> cluster.conf I will have a better idea of what is going on.
> 
> -b
> 
> 
> 
> ----- "Wahyu Darmawan" <wahyu@xxxxxxxxxxxxxx> wrote:
> 
> > Hi all,
> >
> >
> >
> > For fencing, Iâm using HP iLO and server is BL460c G6. Problem is
> > resource is start moving to the passive when the failed node is
> power
> > on. It is really strange for me. For example, I shutdown the node1
> and
> > physically remove the node1 machine from the blade chassis and
> monitor
> > the clustat output, clustat was still showing that the resource is
> on
> > node 1, even node 1 is power down and removed from c7000 blade
> > chassis. But when I plugged again the failed node1 on the c7000
> blade
> > chassis and it power-on, then clustat is showing that the resource
> is
> > start moving to the passive node from the failed node.
> > Iâm powering down the blade server with power button in front of it,
> > then we remove it from the chassis, If we face the hardware problem
> in
> > our active node and the active node goes down then how the resource
> > move to the passive node. In addition, When I rebooted or shutdown
> the
> > machine from the CLI, then the resource moves successfully from the
> > passive node. Furthurmore, When I shutdown the active node with
> > "shutdown -hy 0" command, after shuting down the active node
> > automatically restart.
> >
> > Please help me.
> >
> >
> >
> > Many Thanks,
> > --
> > Linux-cluster mailing list
> > Linux-cluster@xxxxxxxxxx
> > https://www.redhat.com/mailman/listinfo/linux-cluster
> 
> --
> Linux-cluster mailing list
> Linux-cluster@xxxxxxxxxx
> https://www.redhat.com/mailman/listinfo/linux-cluster
> 
> 
> --
> Linux-cluster mailing list
> Linux-cluster@xxxxxxxxxx
> https://www.redhat.com/mailman/listinfo/linux-cluster

--
Linux-cluster mailing list
Linux-cluster@xxxxxxxxxx
https://www.redhat.com/mailman/listinfo/linux-cluster



[Index of Archives]     [Corosync Cluster Engine]     [GFS]     [Linux Virtualization]     [Centos Virtualization]     [Centos]     [Linux RAID]     [Fedora Users]     [Fedora SELinux]     [Big List of Linux Books]     [Yosemite Camping]

  Powered by Linux