Hellos Im testing SAN under Multipath failures and founding a behavior on the fs.sh that is not what I wanned. On simulating a SAN failure either with portdown on the san switch or on the OS ( echo offline > /sys/block/$DEVICE/device/state ) the fs.sh status script doesn't give back an error. I looked at the script and think it hangs on the ls or touch test (depends on timings ) In fact if I issue an ls/touch on the failed mountpoints it hangs forever. If I fail the devices with /sys/block/$DEVICE/device/delete then the touch test returns an error and service switches. I found on redhat doc a reference for a parameter: remove_on_dev_loss http://www.redhat.com/docs/en-US/Red_Hat_Enterprise_Linux/html/Online_Storage_Reconfiguration_Guide/modifying-link-loss-behavior.html I set it echo 1 > /sys/module/scsi_transport_fc/parameters/remove_on_dev_loss but didn't notice any changes Any nice suggestions ? Thanks Jose -- Linux-cluster mailing list Linux-cluster@xxxxxxxxxx https://www.redhat.com/mailman/listinfo/linux-cluster