jr napisał(a): > Hi everybody, > is there a way that i can make the cluster detect faulty nodes such as > failed san paths? > in my case i had a node which lost the connection the san completely but > it wouldn't be fenced because it behaved completely normally in every > other sense, only the i/o got stalled because of the failed paths. > can i somehow make the cluster check that? quorumd + "heuristic program" is the solution Best Regards Maciej Bogucki -- Linux-cluster mailing list Linux-cluster@xxxxxxxxxx https://www.redhat.com/mailman/listinfo/linux-cluster