Re: Faulty node detection

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



jr napisał(a):
> Hi everybody,
> is there a way that i can make the cluster detect faulty nodes such as
> failed san paths?
> in my case i had a node which lost the connection the san completely but
> it wouldn't be fenced because it behaved completely normally in every
> other sense, only the i/o got stalled because of the failed paths.
> can i somehow make the cluster check that?

quorumd + "heuristic program" is the solution

Best Regards
Maciej Bogucki

--
Linux-cluster mailing list
Linux-cluster@xxxxxxxxxx
https://www.redhat.com/mailman/listinfo/linux-cluster