Faulty node detection

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Hi everybody,
is there a way that i can make the cluster detect faulty nodes such as
failed san paths?
in my case i had a node which lost the connection the san completely but
it wouldn't be fenced because it behaved completely normally in every
other sense, only the i/o got stalled because of the failed paths.
can i somehow make the cluster check that?
regards,
johannes

--
Linux-cluster mailing list
Linux-cluster@xxxxxxxxxx
https://www.redhat.com/mailman/listinfo/linux-cluster

[Index of Archives]     [Corosync Cluster Engine]     [GFS]     [Linux Virtualization]     [Centos Virtualization]     [Centos]     [Linux RAID]     [Fedora Users]     [Fedora SELinux]     [Big List of Linux Books]     [Yosemite Camping]

  Powered by Linux