On Mon, 2007-11-19 at 09:50 +0000, Robert Clark wrote: > On Sun, 2007-11-18 at 16:37 +0100, Ante Karamatić wrote: > > > When I run 'fence_node node2', I get: > > [...] > > > fence_apc ends up in Phase Monitor, instead of Outlet Control. It > > opens connection to Control console, then enters Device Manager, and > > then instead of entering Outlet Control (2), it enters Phase Monitor > > (1). > > > > It's an APC AP7920 with firmware v2.7.3. It's an RHCS v2.20070823, from > > Ubuntu 7.10. > Please test the attached if you can, and let me know here if all is OK with your switch. This is the version in the latest update that is to go out next. If this agent script does not fence your node, then we can go to the next step and dump the interaction, and then get this fixed fast. Thanks and Regards, -Jim -- Linux-cluster mailing list Linux-cluster@xxxxxxxxxx https://www.redhat.com/mailman/listinfo/linux-cluster