Hi Mike Could you show the output of cat /proc/scsi/scsi? I think that it can recognize only the drive of LUN number 0. 1. Add the following line to/etc/modprobe.conf. options scsi_mod.o max_scsi_luns=255 2. Next, this setting must be read when you boot OS. #mkinitrd /boot/< your initrd image > `uname -r` Regard ------------------------------------------------------ Shirai Noriyuki Chief Engineer Technical Div. System Create Inc Kanda Toyo Bldg, 3-4-2 Kandakajicho Chiyodaku Tokyo 101-0045 Japan Tel81-3-5296-3775 Fax81-3-5296-3777 e-mail:shirai@xxxxxxxxxx web:http://www.sc-i.co.jp ------------------------------------------------------ > With all of the tech's on this list... no one has seen this problem? > Thought I'd ask again since I'm still stumped. > > By the way, anyone know of any user groups, forums for the Xyratex/MTI style > storage chassis? > > Mike > > >This might or might not be the right list and if it is not, does anyone know > >one that would cover things like fibre channel RAID devices? > > >I have an 800GB RAID drive which I have split into 32 smaller volumes. This > >is a fibre channel system, Xyratex. The problem is that I cannot see any more > >than 2 volumes per controller when I check from any of the nodes. > > >Basically, I would like to set up a small volume for each node along with > >their various GFS volumes. > > > > -- > Linux-cluster mailing list > Linux-cluster@xxxxxxxxxx > https://www.redhat.com/mailman/listinfo/linux-cluster > > > -- Linux-cluster mailing list Linux-cluster@xxxxxxxxxx https://www.redhat.com/mailman/listinfo/linux-cluster