Is this on SSD or HDD? RGW index, RBD, or ...? Those all change the math on single-object recovery time. Having said that...if the object is not huge and is not RGW index omap, that slow of a single-object recovery would have me checking whether I have a bad disk that's presenting itself as significantly underperforming. Josh On Wed, May 11, 2022 at 4:03 PM Harry G. Coin <hgcoin@xxxxxxxxx> wrote: > > Might someone explain why the count of degraded items can drop > thousands, sometimes tens of thousands in the same number of hours it > takes to go from 10 to 0? For example, when an OSD or a host with a few > OSD's goes offline for a while, reboots. > > Sitting at one complete and entire degraded object out of millions for > longer than it took to write this post. > > Seems the fewer the number of degraded objects, the less interested the > cluster is in fixing it! > > HC > > > > _______________________________________________ > ceph-users mailing list -- ceph-users@xxxxxxx > To unsubscribe send an email to ceph-users-leave@xxxxxxx _______________________________________________ ceph-users mailing list -- ceph-users@xxxxxxx To unsubscribe send an email to ceph-users-leave@xxxxxxx