Yes. After the time-out of 600 secs the OSDs got marked down, all PGs got remapped and recovery/rebalancing started as usual. In the past, I did service on servers with the flag noout set and would expect that mon_osd_down_out_subtree_limit=host has the same effect when shutting down an entire host. Unfortunately, in my case these two settings behave differently. If I understand the documentation correctly, the OSDs should not get marked out automatically. Best regards, ================= Frank Schilder AIT Risø Campus Bygning 109, rum S14 ________________________________________ From: Anthony D'Atri <anthony.datri@xxxxxxxxx> Sent: 14 July 2020 04:32:05 To: Frank Schilder Subject: Re: mon_osd_down_out_subtree_limit not working? Did it start rebalancing? > On Jul 13, 2020, at 4:29 AM, Frank Schilder <frans@xxxxxx> wrote: > > if I shut down all OSDs on this host, these OSDs should not be marked out automatically after mon_osd_down_out_interval(=600) seconds. I did a test today and, unfortunately, the OSDs do get marked as out. Ceph status was showing 1 host down as expected. _______________________________________________ ceph-users mailing list -- ceph-users@xxxxxxx To unsubscribe send an email to ceph-users-leave@xxxxxxx