> I'm not sure why the monitor did not mark it _out_ after 600 seconds > (default) Well, that part I understand. The monitor didn't mark the OSD out because the monitor still considered the OSD up. No reason to mark an up OSD out. I think the monitor should have marked the OSD down upon not hearing from it for 15 minutes ("mon osd report interval"), then out 10 minutes after that ("mon osd down out interval"). And that's worst case. Though details of how OSDs watch each other are vague, I suspect an existing OSD was supposed to detect the dead OSDs and report that to the monitor, which would believe it within about a minute and mark the OSDs down. ("osd heartbeat interval", "mon osd min down reports", "mon osd min down reporters", "osd reporter subtree level"). -- Bryan Henderson San Jose, California _______________________________________________ ceph-users mailing list ceph-users@xxxxxxxxxxxxxx http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com