Re: Fwd: HW failure cause client IO drops

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Good morning,

the OSDs are usually marked out after 10 minutes, that's when rebalancing starts. But the I/O should not drop during that time, this could be related to your pool configuration. If you have a replicated pool of size 3 and also set min_size to 3 the I/O would pause if a node or OSD fails. So more information about the cluster would help, can you share that?

ceph osd tree
ceph osd pool ls detail

Were all pools affected or just specific pools?

Regards,
Eugen


Zitat von M Ranga Swami Reddy <swamireddy@xxxxxxxxx>:

Hello - Recevenlt we had an issue with storage node's battery failure,
which cause ceph client IO dropped to '0' bytes. Means ceph cluster
couldn't perform IO operations on the cluster till the node takes out. This
is not expected from Ceph, as some HW fails, those respective OSDs should
mark as out/down and IO should go as is..

Please let me know if anyone seen the similar behavior and is this issue
resolved?

Thanks
Swami



_______________________________________________
ceph-users mailing list
ceph-users@xxxxxxxxxxxxxx
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com