Re: two OSDs with high out rate

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 




On 1/10/19 12:59 PM, Marc wrote:
> Hi,
> 
> for support reasons we're still running firefly (part of MCP 6). In our
> grafana monitoring we noticed that two out of 128 OSD processes show
> significantly higher outbound IO than all the others and this is
> constant (cant see first occurance of this anymore, grafana only has 14
> days backlog). Those 2 show 350MB/s out whereas all the other are at
> 50MB/s - constantly. There's obviously spikes that go above that but
> that seems to be idle / normal rate throughout the day.
> 
> Is there a good way to debug this with standard tools (i.e. no sysdig /
> nmon)? See which IP this goes to and/or what object/s this is caused by?
> Ceph is only serving KVM images as is default for most installations I
> suppose.
> 

You could increase debug ms and debug rados on the OSDs and see which
operations they are doing.

Try with 10 and 20 for both values to see what the OSDs are doing.

Wido

> 
> Thanks!
> M.
> _______________________________________________
> ceph-users mailing list
> ceph-users@xxxxxxxxxxxxxx
> http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com
_______________________________________________
ceph-users mailing list
ceph-users@xxxxxxxxxxxxxx
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com



[Index of Archives]     [Information on CEPH]     [Linux Filesystem Development]     [Ceph Development]     [Ceph Large]     [Linux USB Development]     [Video for Linux]     [Linux Audio Users]     [Yosemite News]     [Linux Kernel]     [Linux SCSI]     [xfs]


  Powered by Linux