Re: Crush Map Changed After Reboot

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Fwir, you could also put this into your ceph.conf to explicitly put an osd into the correct chassis at start if you have other osd's which you still want the crush_update_on_start setting set to true for:

[osd.34]
       osd crush location = "chassis=ceph-osd3-internal"
[osd.35]
       osd crush location = "chassis=ceph-osd3-internal"

etc..

Kind regards,
Caspar

2018-05-22 3:03 GMT+02:00 David Turner <drakonstein@xxxxxxxxx>:
Your problem sounds like osd_crush_update_on_start.  While set to the default of true, when an osd starts it tells the mons which server it is on and the mons will update the crush map to reflect it. While these osds running on the host, but placed in a custom host in the crush map... when they start they will update to show which host they are running on.  You probably want to disable that in the config so that your custom crush placement is not altered.


On Mon, May 21, 2018, 6:29 PM Martin, Jeremy <jmartin@xxxxxxxx> wrote:
Hello,

I had a ceph cluster up and running for a few months now and all has been well and good except for today where I updated two osd nodes and well still well, these two nodes are designated within a rack and the rack is the failure domain so they are essentially mirrors of each.  The issue came when I updated and rebooted the third node which has internal and external disks in a shelf and the failure domain is at the actual osd level as these are normal off the shelf disks for low priority storage that is not mission critical.  The issue is that before the reboot the crush map look and behaved correctly but after the reboot the crush map was changed and had to be rebuilt to get the storage back online, all was well after the reassignment by I need to track down why it lots it configuration.  The main differences here is that the first four disks (34-37) are supposed to be assigned to the chassis ceph-osd3-internal (like the before) and 21-31 assigned to chassis chassis-ceph-osd3-shelf1
 (again like the before).  After the reboot everything (34-37 and 21-31) was reassigned to the host ceph-osd3.  Update was from 12.2.4 to 12.2.5.  Any thoughts? 

Jeremy

Before

ID  CLASS WEIGHT   TYPE NAME                      STATUS REWEIGHT PRI-AFF
-58              0 root osd3-internal
-54              0     chassis ceph-osd3-internal
 34   hdd  0.42899         osd.34                     up  1.00000 1.00000
 35   hdd  0.42899         osd.35                     up  1.00000 1.00000
 36   hdd  0.42899         osd.36                     up  1.00000 1.00000
 37   hdd  0.42899         osd.37                     up  1.00000 1.00000
-50              0 root osd3-shelf1
-56              0     chassis ceph-osd3-shelf1
 21   hdd  1.81898         osd.21                     up  1.00000 1.00000
 22   hdd  1.81898         osd.22                     up  1.00000 1.00000
 23   hdd  1.81898         osd.23                     up  1.00000 1.00000
 24   hdd  1.81898         osd.24                     up  1.00000 1.00000
 25   hdd  1.81898         osd.25                     up  1.00000 1.00000
 26   hdd  1.81898         osd.26                     up  1.00000 1.00000
 27   hdd  1.81898         osd.27                     up  1.00000 1.00000
 28   hdd  1.81898         osd.28                     up  1.00000 1.00000
 29   hdd  1.81898         osd.29                     up  1.00000 1.00000
 30   hdd  1.81898         osd.30                     up  1.00000 1.00000
 31   hdd  1.81898         osd.31                     up  1.00000 1.00000
 -7              0 host ceph-osd3
 -1       47.21199 root default
-40       23.59000     rack mainehall
 -3       23.59000         host ceph-osd1
  0   hdd  1.81898             osd.0                  up  1.00000 1.00000
      Additional osd's left off for brevity
-5       23.62199         host ceph-osd2
 11   hdd  1.81898             osd.11                 up  1.00000 1.00000
      Additional osd's left off for brevity

After

ID  CLASS WEIGHT   TYPE NAME                      STATUS REWEIGHT PRI-AFF
-58              0 root osd3-internal
-54              0     chassis ceph-osd3-internal
-50              0 root osd3-shelf1
-56              0     chassis ceph-osd3-shelf1
-7               0 host ceph-osd3
 21   hdd  1.81898         osd.21                     up  1.00000 1.00000
 22   hdd  1.81898         osd.22                     up  1.00000 1.00000
 23   hdd  1.81898         osd.23                     up  1.00000 1.00000
 24   hdd  1.81898         osd.24                     up  1.00000 1.00000
 25   hdd  1.81898         osd.25                     up  1.00000 1.00000
 26   hdd  1.81898         osd.26                     up  1.00000 1.00000
 27   hdd  1.81898         osd.27                     up  1.00000 1.00000
 28   hdd  1.81898         osd.28                     up  1.00000 1.00000
 29   hdd  1.81898         osd.29                     up  1.00000 1.00000
 30   hdd  1.81898         osd.30                     up  1.00000 1.00000
 31   hdd  1.81898         osd.31                     up  1.00000 1.00000
 34   hdd  0.42899         osd.34                     up  1.00000 1.00000
 35   hdd  0.42899         osd.35                     up  1.00000 1.00000
 36   hdd  0.42899         osd.36                     up  1.00000 1.00000
 37   hdd  0.42899         osd.37                     up  1.00000 1.00000
 -1       47.21199 root default
-40       23.59000     rack mainehall
 -3       23.59000         host ceph-osd1
  0   hdd  1.81898             osd.0                  up  1.00000 1.00000
      Additional osd's left off for brevity
-42       23.62199     rack rangleyhall
 -5       23.62199         host ceph-osd2
 11   hdd  1.81898             osd.11                 up  1.00000 1.00000
      Additional osd's left off for brevity
_______________________________________________
ceph-users mailing list
ceph-users@xxxxxxxxxxxxxx
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com

_______________________________________________
ceph-users mailing list
ceph-users@xxxxxxxxxxxxxx
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com


_______________________________________________
ceph-users mailing list
ceph-users@xxxxxxxxxxxxxx
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com

[Index of Archives]     [Information on CEPH]     [Linux Filesystem Development]     [Ceph Development]     [Ceph Large]     [Ceph Dev]     [Linux USB Development]     [Video for Linux]     [Linux Audio Users]     [Yosemite News]     [Linux Kernel]     [Linux SCSI]     [xfs]


  Powered by Linux