radosgw 100-continue problem

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Hi:
I used nginx + fastcti  + radosgw , when configure radosgw with "rgw
print continue = true " In RFC 2616 , it says  An origin server that
sends a 100 (Continue) response MUST ultimately send a final status
code, once the request body is received and processed, unless it
terminates the transport connection prematurely. But in RADOSGW,  for
PUT requests, when radosgw receive EXCEPT: 100-continue, it responds
100-continue , the code is like this
int RGWFCGX::send_status(int status, const char *status_name)
{
  status_num = status;
  return print("Status: %d %s\r\n", status, status_name);
}
int RGWFCGX::send_100_continue()
{
  int r = send_status(100, "Continue");
  if (r >= 0) {
    flush();
  }
  return r;
}

there is just one \r\n, this means the header is not end. So when it
run to send_response(), it continue to send the rest header. I wonder
if this is the cause. Nginx doesn't work due to this.  I think this
should split into two response.