Ok. Are you using O_DIRECT? That will disable readahead on the client,
but if you don't use O_DIRECT you won't get the benefit of iodepth=16.
See fio's man page:
"Number of I/O units to keep in flight against the file. Note that
increasing iodepth beyond 1 will not affect synchronous ioengines
(except for small degress when verify_async is in use). Even async
engines my impose OS restrictions causing the desired depth not to be
achieved. This may happen on Linux when using libaio and not setting
direct=1, since buffered IO is not async on that OS. Keep an eye on the
IO depth distribution in the fio output to verify that the achieved
depth is as expected. Default: 1."
IE, how you are testing could really affect the ability to do
client-side readahead and may affect how much client-side concurrency
you are getting.
Mark
On 07/27/2016 10:14 AM, EP Komarla wrote:
I am using aio engine in fio.
Fio is working on rbd images
- epk
-----Original Message-----
From: ceph-users [mailto:ceph-users-bounces@xxxxxxxxxxxxxx] On Behalf Of Mark Nelson
Sent: Tuesday, July 26, 2016 6:27 PM
To: ceph-users@xxxxxxxxxxxxxx
Subject: Re: Ceph performance pattern
Hi epk,
Which ioengine are you using? if it's librbd, you might try playing with librbd readahead as well:
# don't disable readahead after a certain number of bytes rbd readahead disable after bytes = 0
# Set the librbd readahead to whatever:
rbd readahead max bytes = 4194304
If it's with kvm+guests, you may be better off playing with the guest readahead but you can try the librbd readahead if you want.
Another thing to watch out for is fragmentation. btrfs OSDs for example will fragment terribly after small random writes to RBD images due to how copy-on-write works. That can cause havoc with RBD sequential reads in general.
Mark
On 07/26/2016 06:38 PM, EP Komarla wrote:
Hi,
I am showing below fio results for Sequential Read on my Ceph cluster.
I am trying to understand this pattern:
- why there is a dip in the performance for block sizes 32k-256k?
- is this an expected performance graph?
- have you seen this kind of pattern before
My cluster details:
Ceph: Hammer release
Cluster: 6 nodes (dual Intel sockets) each with 20 OSDs and 4 SSDs (5
OSD journals on one SSD)
Client network: 10Gbps
Cluster network: 10Gbps
FIO test:
- 2 Client servers
- Sequential Read
- Run time of 600 seconds
- Filesize = 1TB
- 10 rbd images per client
- Queue depth=16
Any ideas on tuning this cluster? Where should I look first?
Thanks,
- epk
Legal Disclaimer:
The information contained in this message may be privileged and
confidential. It is intended to be read only by the individual or
entity to whom it is addressed or by their designee. If the reader of
this message is not the intended recipient, you are on notice that any
distribution of this message, in any form, is strictly prohibited. If
you have received this message in error, please immediately notify the
sender and delete or destroy any copy of this message!
_______________________________________________
ceph-users mailing list
ceph-users@xxxxxxxxxxxxxx
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com
_______________________________________________
ceph-users mailing list
ceph-users@xxxxxxxxxxxxxx
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com
Legal Disclaimer:
The information contained in this message may be privileged and confidential. It is intended to be read only by the individual or entity to whom it is addressed or by their designee. If the reader of this message is not the intended recipient, you are on notice that any distribution of this message, in any form, is strictly prohibited. If you have received this message in error, please immediately notify the sender and delete or destroy any copy of this message!
_______________________________________________
ceph-users mailing list
ceph-users@xxxxxxxxxxxxxx
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com