Re: "full ratio" - how does this work with multiple pools on seprate OSDs?

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Here is another full ratio scenario:

Let's say that the cluster map is configured as follows:

          Row
             |
    --------------
    |               |
Rack1      Rack2
    |               |
Host1       Host4
Host2       Host5
Host3       Host6

...with a ruleset that distributes replicas across the two rack buckets (i.e. using Rack1 and Rack2 as failure domains)

If the used capacity is more that 2/3rds full but less than 5/6 full and one of the hosts fail, will Ceph rebalance using all capacity available in both Rack buckets and continue running, or only rebalance in one rack bucket, resulting in exceeding the full ratio and locking up?

Thanks,

-Tom

-----Original Message-----
From: Gregory Farnum [mailto:greg@xxxxxxxxxxx] 
Sent: Tuesday, March 04, 2014 10:10 AM
To: Barnes, Thomas J
Cc: ceph-users@xxxxxxxx
Subject: Re:  "full ratio" - how does this work with multiple pools on seprate OSDs?

The setting is calculated per-OSD, and if any OSD hits the hard limit the whole cluster transitions to the full state and stops accepting writes until the situation is resolved.
-Greg
Software Engineer #42 @ http://inktank.com | http://ceph.com


On Tue, Mar 4, 2014 at 9:58 AM, Barnes, Thomas J <thomas.j.barnes@xxxxxxxxx> wrote:
> I have a question about how "full ratio" works.
>
>
>
> How does a single "full ratio" setting work when the cluster has pools 
> associated with different drives?
>
>
>
> For example, let's say I have a cluster comprised of fifty 10K RPM 
> drives and fifty 7200 RPM drives.  I segregate the 10K drives and 
> 7200RM drives under separate buckets, create separate rulesets for 
> each bucket, and create separate pools for each bucket (using each buckets respective ruleset).
>
>
>
> What happens if one of the pools fills to capacity while the other 
> pool remains empty?
>
> How does the cluster respond when the OSDs in one pool become full 
> while the OSDs in other pools do not?
>
> Is full ratio calculated over the entire cluster or "by pool"?
>
>
>
> Thanks,
>
>
>
> -Tom
>
>
>
>
> _______________________________________________
> ceph-users mailing list
> ceph-users@xxxxxxxxxxxxxx
> http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com
>
_______________________________________________
ceph-users mailing list
ceph-users@xxxxxxxxxxxxxx
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com




[Index of Archives]     [Information on CEPH]     [Linux Filesystem Development]     [Ceph Development]     [Ceph Large]     [Linux USB Development]     [Video for Linux]     [Linux Audio Users]     [Yosemite News]     [Linux Kernel]     [Linux SCSI]     [xfs]