That's useful information.
2014/1/3 Wido den Hollander <wido@xxxxxxxx>
You manually have to instruct the OSD to repair the PG.On 01/02/2014 04:00 PM, Kuo Hugo wrote:
Hi all,
I did a test to ensure Rados's recovering.
1. echo string into a object from a placement group's directory on a OSD.
2. After osd scrub, the ceph health shows " 1pgs inconsistent " . Will
it be fixed later?
iirc it's: ceph pg repair <pg id>
Thanks
_______________________________________________
ceph-users mailing list
ceph-users@xxxxxxxxxxxxxx
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com
--
Wido den Hollander
42on B.V.
Phone: +31 (0)20 700 9902
Skype: contact42on
_______________________________________________
ceph-users mailing list
ceph-users@xxxxxxxxxxxxxx
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com
_______________________________________________ ceph-users mailing list ceph-users@xxxxxxxxxxxxxx http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com