On Sunday, February 24, 2013 at 2:59 PM, Andrey Korolyov wrote: > On Mon, Feb 25, 2013 at 2:49 AM, Gregory Farnum <greg@xxxxxxxxxxx (mailto:greg@xxxxxxxxxxx)> wrote: > > On Sunday, February 24, 2013 at 2:42 PM, Andrey Korolyov wrote: > > > On Mon, Feb 25, 2013 at 2:37 AM, Gregory Farnum <greg@xxxxxxxxxxx (mailto:greg@xxxxxxxxxxx)> wrote: > > > > On Sunday, February 24, 2013 at 1:48 PM, Andrey Korolyov wrote: > > > > > Hi, > > > > > > > > > > "filestore_queue_max_ops": "50", > > > > > "filestore_flusher": "true", > > > > > > > > > > Just checked that this options are set with values above instead of > > > > > config` 500 and 0 as mentioned in docs, and second option has an > > > > > observable performance impact when enabled. > > > > > > > > > > > > > > > > > > > > > > > > Defaults get changed fairly often and I'm not sure when that doc was created — it was probably for argonaut. Sorry if it's causing you trouble! > > > > > > > > > > > > > Also there is some wild > > > > > magic, I`m not able to set bool value to the false at runtime, instead > > > > > of it, value dropped to true even if set to false at start of an osd > > > > > in config: > > > > > > > > > > ceph --keyfile admin osd tell \* injectargs "--filestore-flusher 0" > > > > > > > > > > 2013-02-25 01:17:29.255987 osd.14 [INF] failed to parse arguments: 0 > > > > > 2013-02-25 01:17:29.256006 osd.14 [INF] applying configuration change: > > > > > filestore_flusher = 'true' > > > > > > > > > > > > > > > > > > > > > > > > I don't remember if "0" is supposed to work in this case or not — but "false" should. Try that? > > > > -Greg > > > > > > > > > > > > > > > > > > I have tried in different combinations, involving 0 and false, with > > > and without quotations, no success at all. Meanwhile, modifying any > > > integer value works well, so it is boolean-specific issue. > > > > > > > > What version are you using? I can't find the output you're citing anywhere in current master. > > Oh, sorry, forgot to add - 290a352c3f9e241deac562e980ac8c6a74033ba6 > from bobtail branch, both binaries and running instances. Try ceph --keyfile admin osd tell \* injectargs "--filestore-flusher=0" (add the equals sign) and let me know if that works. Looks like maybe the boolean parser isn't accepting space-separated option/value pairs. -Greg _______________________________________________ ceph-users mailing list ceph-users@xxxxxxxxxxxxxx http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com