Re: Differences between default config values and docs

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Mon, Feb 25, 2013 at 2:37 AM, Gregory Farnum <greg@xxxxxxxxxxx> wrote:
> On Sunday, February 24, 2013 at 1:48 PM, Andrey Korolyov wrote:
>> Hi,
>>
>> "filestore_queue_max_ops": "50",
>> "filestore_flusher": "true",
>>
>> Just checked that this options are set with values above instead of
>> config` 500 and 0 as mentioned in docs, and second option has an
>> observable performance impact when enabled.
>
> Defaults get changed fairly often and I'm not sure when that doc was created — it was probably for argonaut. Sorry if it's causing you trouble!
>
>
>> Also there is some wild
>> magic, I`m not able to set bool value to the false at runtime, instead
>> of it, value dropped to true even if set to false at start of an osd
>> in config:
>>
>> ceph --keyfile admin osd tell \* injectargs "--filestore-flusher 0"
>>
>> 2013-02-25 01:17:29.255987 osd.14 [INF] failed to parse arguments: 0
>> 2013-02-25 01:17:29.256006 osd.14 [INF] applying configuration change:
>> filestore_flusher = 'true'
>
> I don't remember if "0" is supposed to work in this case or not — but "false" should. Try that?
> -Greg
>

I have tried in different combinations, involving 0 and false, with
and without quotations, no success at all. Meanwhile, modifying any
integer value works well, so it is boolean-specific issue.