On 10/09/2012 03:14 PM, James Horner wrote:
Hi There




I have a simple test cluster spread across 2 datacenters setup as follows

DC1:
mon.w
mon.x
mds.w
mds.x
osd1

DC2:
mon.e
mds.e
osd2

Each DC has a hypervisor(Proxmox running qemu 1.1.1) which can connect to the cluster fine. I think I have the crush map setup to replicate between the datacenters but when I run a VM with a disk on the cluster the hv's connect to the OSD's in the other datacenter. Is there a way to tell qemu that it is DC1 or DC2 and to prefer those osd's?


No, there is no such way. Ceph is designed to work on a local network where it doesn't matter where the nodes are or how the client connects.

You are not the first to ask this question. People having been thinking about localizing data, but there have been no concrete plans.

(See note on crushmap below btw)

Thanks.
James



# begin crush map

# devices
device 0 osd.0
device 1 osd.1

# types
type 0 osd
type 1 host
type 2 rack
type 3 row
type 4 room
type 5 datacenter
type 6 pool

# buckets
host ceph-test-dc1-osd1 {
id -2 # do not change unnecessarily
# weight 1.000
alg straw
hash 0 # rjenkins1
item osd.0 weight 1.000
}
host ceph-test-dc2-osd1 {
id -4 # do not change unnecessarily
# weight 1.000
alg straw
hash 0 # rjenkins1
item osd.1 weight 1.000
}
rack dc1-rack1 {
id -3 # do not change unnecessarily
# weight 2.000
alg straw
hash 0 # rjenkins1
item ceph-test-dc1-osd1 weight 1.000
}


You don't need to specify a weight to the rack in this case, it will take the accumulated weight of all the hosts it has in it.

rack dc2-rack1 {
id -5
alg straw
hash 0
item ceph-test-dc2-osd1 weight 1.000
}

datacenter dc1 {
id -6
alg straw
hash 0
item dc1-rack1 weight 1.000
}

datacenter dc2 {
id -7
alg straw
hash 0
item dc2-rack1 weight 1.000
}

pool proxmox {
id -1 # do not change unnecessarily
# weight 2.000
alg straw
hash 0 # rjenkins1
item dc1 weight 2.000
item dc2 weight 2.000
}



Same goes here, the dc's get their weight by summing up the racks and hosts.

While in your case it doesn't matter that much, you should let crush do the calculating when possible.

Wido

# rules
rule proxmox {
ruleset 0
type replicated
min_size 1
max_size 10
step take default
step chooseleaf firstn 0 type datacenter

step emit
}


# end crush map


--
To unsubscribe from this list: send the line "unsubscribe ceph-devel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html


--
To unsubscribe from this list: send the line "unsubscribe ceph-devel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html


[Index of Archives]     [CEPH Users]     [Ceph Large]     [Information on CEPH]     [Linux BTRFS]     [Linux USB Devel]     [Video for Linux]     [Linux Audio Users]     [Yosemite News]     [Linux Kernel]     [Linux SCSI]
  Powered by Linux