Re: software raid1 syncing

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]



On Fri, Jul 3, 2009 at 9:15 PM, Steven Vishoot<sir_funzone@xxxxxxxxx> wrote:
>
> hello all,
>
> I have a setup that is raid 1 and put the mirrored drive back in and now it is still showing as degraded saying: raid1: raid set md6 active with 1 out of 2 mirrors with this message on all the raids.i know i am wrong by saying this but i thought putting in the driving and rebooting would start the re syncing itself. what do i have to do to add this back in, i am so confused with this process.
>
> centos 4.x
>
> _______________________________________________
> CentOS mailing list
> CentOS@xxxxxxxxxx
> http://lists.centos.org/mailman/listinfo/centos
>

Well, just putting a new disk drive in the place of the bad one
doesn't cut it. You have to recreate partition table and then add the
partitions to the drive.
e.g.
sda = the old disk in the raid that has not failed
sdb = the newly added disk
dd if=/dev/sda of=/dev/sdb bs=512 count=1

That'll replicate the partition table and mbr to the new disk.

Then starting addinf the new partitions to the linux raid:
mdadm -a /dev/sdb1 /dev/md0 and so on, depending what your setup is.
Do a:
cat /proc/mdstat and see what partitions are added to which raid.
Alternatively to a google search for howtos (e.g.
http://www.gagme.com/greg/linux/raid-lvm.php ) and learn how to manage
linux raid so you dont fsck up your system.
_______________________________________________
CentOS mailing list
CentOS@xxxxxxxxxx
http://lists.centos.org/mailman/listinfo/centos

[Index of Archives]     [CentOS]     [CentOS Announce]     [CentOS Development]     [CentOS ARM Devel]     [CentOS Docs]     [CentOS Virtualization]     [Carrier Grade Linux]     [Linux Media]     [Asterisk]     [DCCP]     [Netdev]     [Xorg]     [Linux USB]
  Powered by Linux