Jeff Lasman wrote:
if the hardware can hotswap then you should be ok if i am reading
what les said correctly.
From time to time (not now) I have a machine on my testbed I can test
this on.
Should I break the software RAID first? I'd think so.
No, you'd expect a failure to automatically kick the drive out of the
raid and go on about its business.
Do I have to remake the RAID automatically? I'd think so.
Yes, you have to 'mdadm --add ...' to make the replacement sync back up.
Can I physically damage either drive?
I'd think not.
So I'm not sure I understand the problem as long as the (sata) drive is
in a hotswap bay.
Anything I'm missing?
The question is whether the kernel will notice the new drive when you
add it. It might be possible to swap in an exact match and get away
with the setup detected at boot time but that doesn't sound very
healthy. Can you hotswap a new SATA drive that wasn't present at boot
time and have the kernel notice the new drive device and its partitions.
If the partitions are recognized, mdadm will be able to add them.
--
Les Mikesell
lesmikesell@xxxxxxxxx
_______________________________________________
CentOS mailing list
CentOS@xxxxxxxxxx
http://lists.centos.org/mailman/listinfo/centos