This can be caused by overheating. If the drives are mounted close
together as some chassis configurations permit, then it make sense they
may both exhibit the same problem, but not necessarily simultaneously. Are this log entries adjacent to each other? P. Scott Silva wrote: Bowie Bailey spake the following on 9/21/2006 12:56 PM:One of my CentOS boxes has started giving me errors. The box is CentOS-4.4 (i386) fully updated. It has a pair of SATA drives in a software raid 1 configuration. The errors I see are: ata1: command 0xca timeout, stat 0x50 host_stat 0x24 ata1: status=0x50 { DriveReady SeekComplete } Info fld=0x1e22b8, Current sda: sense key No Sense ata2: command 0xca timeout, stat 0x50 host_stat 0x24 ata2: status=0x50 { DriveReady SeekComplete } Info fld=0x1e2598, Current sdb: sense key No Sense If it was just coming from one drive, I would say it was a bad drive, but this is happening on both drives. Can anyone give me a starting place to diagnose this? Thanks. -- BowieCables? Connections? Power supply going bad? -- This message has been scanned for viruses and dangerous content by the Enhancion system scanner, and is believed to be clean. |
_______________________________________________ CentOS mailing list CentOS@xxxxxxxxxx http://lists.centos.org/mailman/listinfo/centos