Hi Yuriy, > Can you tell me, please, how many concurrent connections (i mean > proccess of connection) can be done on one dongle? > > for example: > > hcitool con > Connections: > < ACL 00:1C:9A:6E:27:4A handle 0 state 5 lm MASTER > < ACL 00:16:BC:31:EE:2E handle 0 state 5 lm MASTER > < ACL 00:16:B8:AE:75:7E handle 3 state 1 lm MASTER > < ACL 00:18:0F:AC:BF:EE handle 2 state 1 lm MASTER > < ACL 00:1E:4C:D4:0C:52 handle 1 state 1 lm MASTER > > Does "handle 0" mean that there is a try of low level connection? > > I've not seen "handle 0" more then 3 times. decode the state. It is BT_CONNECT. And actually only one connect attempt can be made at a time. Some hardware queues it for you. For others we have to do it and then this should show state BT_CONNECT2. Regards Marcel ------------------------------------------------------------------------- This SF.Net email is sponsored by the Moblin Your Move Developer's challenge Build the coolest Linux based applications with Moblin SDK & win great prizes Grand prize is a trip for two to an Open Source event anywhere in the world http://moblin-contest.org/redirect.php?banner_id=100&url=/ _______________________________________________ Bluez-devel mailing list Bluez-devel@xxxxxxxxxxxxxxxxxxxxx https://lists.sourceforge.net/lists/listinfo/bluez-devel