On Jan 10, 2011 9:59 AM, "Wasim Baig" <wasim at convergence.pk> wrote: > > On Sun, Jan 9, 2011 at 23:18, Benaiad <benaiad at gmail.com> wrote: >> >> Hi, >> >> ;First of all, I'm newbie in this field, so please forgive my unprofessional explanation. >> >> >> I'm trying to connect to a mobile operator with chan_ss7 using sangoma card. >> the telecom regulator initiated an SPC code for us >> Now, the operator's engineer asked me for the following parameters: >> OPC , Link type , TS , SLC. > > > Ideally, they should give a Point Code for you as well, if they don't, you can choose any > arbitrary figure like "1234" or "1" or "69". But where do i configure the SPC then? > >> >> but I don't know what should I provide to him. >> I think the OPC similar to our SPC, And the Link type is 64k, >> But for TS and SLC, I don't know what to say. > > > TS is the timeslot/chan on which you will send signalling. On each E1 you have 31 TS. > Normally 16 is used, although you can use any 1 to 31. > > Use SLC=0 for the first link. > Thanks a lot, shokran, merci, gratci. Regards, -- Benaiad > > > > > -- > wasim h. baig | principal consultant | convergence pk | +92 30 0850 8070 | peace be upon you -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://lists.digium.com/pipermail/asterisk-ss7/attachments/20110111/36273f96/attachment.htm>